ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-175
P5-31 AC11 Acceleration/Deceleration Time (Number #11)
Address: 053EH
053FH
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
3000
Control
Mode:
PR
Unit:
ms
Range:
1 ~ 65500
Data Size:
16-bit
Format:
Decimal
Settings:
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-32 AC12 Acceleration/Deceleration Time (Number #12)
Address: 0540H
0541H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
5000
Control
Mode:
PR
Unit:
ms
Range:
1 ~ 65500
Data Size:
16-bit
Format:
Decimal
Settings:
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-33 AC13 Acceleration/Deceleration Time (Number #13)
Address: 0542H
0543H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
8000
Control
Mode:
PR
Unit:
ms

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals