Chapter 8  Parameters  ASDA-A2 
8-200     Revision February, 2017 
 
Settings: 
When synchronous capture axis is operating, the synchronous error 
should be 0. This parameter shows this error value. The followings are 
its concept: 
Synchronous Error = Output value of synchronous axis-Setting 
value of synchronous axis 
  =  the accumulative amount of P5-77-(P5-78 x 
Capturing number of times) 
When capturing the data, the synchronous axis works normally. This 
parameter updates once. 
This parameter can be written into as well. It indicates the offset of 
synchronous master. When the synchronous capture axis is regarded 
as the master of flying shear, modify this parameter can deviate the 
cutting position to the left/right. 
NOTE
 A2L does not support E-Cam function. 
 
P5-80    CSDS 
Max. Correction Rate of Synchronous Capture 
Axis 
Address: 05A0H 
05A1H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
10 
 
Control 
Mode: 
ALL 
 
Unit: 
% 
 
Range: 
0 ~ 90 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
This parameter limits the percentage (%) of synchronous adjustment. 
Correctionrate
 pulsenumberoutputbysynchronousaxis
/pulsenumberinputbysynchronousaxis
100  P5
80
%    100  5  80% 
The bigger correction rate, the faster the synchronous error becomes 
0. However, the speed changing will be more severe. 
The smaller correction rate, the slower the synchronous error becomes 
0. However, the speed changing will be smoother. 
In the application of flying shear, after adjusting the synchronous error, 
P5-79: the bigger parameter value will reduce the time the slave axis 
goes to the desired position. However, the speed is not synchronized. 
NOTE
 A2L does not support E-Cam function.