ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-93
P2-04 KVP Speed Loop Gain
Address: 0208H
0209H
Operational
Interface
Panel / Software Communication
Related Section:
6.3.6
Default
500
Control
Mode
ALL
Unit
rad/s
Range
0 ~ 8191
Data Size
16-bit
Format
Decimal
Settings
Increase the value of speed loop gain can enhance the speed
response. However, if the value is set too big, it would easily cause
resonance and noise.
P2-05 SPR Switching Rate of Speed Loop Gain
Address: 020AH
020BH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
100
Control
Mode
ALL
Unit
%
Range
10 ~ 500
Data Size
16-bit
Format
Decimal
Settings
Switch the changing rate of speed loop gain according to the gain
switching condition.