Chapter 8 Parameters ASDA-A2
8-94 Revision February, 2017
P2-06 KVI Speed Integral Compensation
Address: 020CH
020DH
Operational
Interface
Panel / Software Communication
Related Section:
6.3.6
Default
100
Control
Mode
ALL
Unit
rad/s
Range
0 ~ 1023
Data Size
16-bit
Format
Decimal
Settings
Increasing the value of speed integral compensation can enhance
speed response and diminish the deviation of speed control. However,
if the value is set too big, it would easily cause resonance and noise.
P2-07 KVF Speed Feed Forward Gain
Address: 020EH
020FH
Operational
Interface
Panel / Software Communication
Related Section:
6.3.6
Default
0
Control
Mode
ALL
Unit
%
Range
0 ~ 100
Data Size
16-bit
Format
Decimal
Settings
When the speed control command runs smoothly, increasing the gain
value can reduce the speed command error. If the command does not
run smoothly, decreasing the gain value can reduce the mechanical
vibration during operation.