ASDA-A2 Chapter 10 Troubleshooting
10-32 Revision February, 2017
AL132
Enter the incorrect password when using
CANopen PDO
NMT: Reset node or 0x6040.Fault
Reset
AL170
Heartbeat or NodeGuarding error
NMT: Reset node or 0x6040.Fault
Reset
AL180
Heartbeat or NodeGuarding error
NMT: Reset node or 0x6040.Fault
Reset
AL185
Abnormal CAN Bus hardware
NMT: Reset node or re-servo on
AL186
CAN bus off
NMT: Reset node or 0x6040.Fault
Reset
AL201
An error occurs when loading CANopen
data
Turn DI.ARST on to clear the alarm.
CANopen 0x1011 Restore default
parameter
AL207
Parameter group of PR#8 is out of range
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
AL209
Parameter number of PR#8 is out of range
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
AL213
A
n error occurs when writing parameter via
PRexceeds the range
DI.Alm Reset or P0-01 = 0
AL215
A
n error occurs when writing parameter via
PRread-only
DI.Alm Reset or P0-01 = 0
AL217
A
n error occurs when writing parameter via
PRparameter locked
Re-adjust PR command and parameter
AL231
The setting of monitor item of PR#8 is out
of range
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
AL235
PR command overflows
NMT: Reset node or 0x6040.Fault
Reset
AL237
Indexing coordinate is undefined
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
AL283
Forward Software Limit
NMT: Reset node or 0x6040.Fault
Reset
AL285
Reverse Software Limit
NMT: Reset node or 0x6040.Fault
Reset
AL289
Feedback position counter overflows
NMT: Reset node or 0x6040.Fault
Reset
AL291
Servo Off error
NMT: Reset node or 0x6040.Fault
Reset