Chapter 10 Troubleshooting ASDA-A2
Revision February, 2017 10-33
AL301
CANopen fails to synchronize
NMT: Reset node or 0x6040.Fault
Reset
AL302
The synchronized signal of CANopen is
sent too fast
NMT: Reset node or 0x6040.Fault
Reset
AL303
The synchronized signal of CANopen is
sent too slow
NMT: Reset node or 0x6040.Fault
Reset
AL304
CANopen IP command is failed
NMT: Reset node or 0x6040.Fault
Reset
AL305
SYNC Period is in error
NMT: Reset node or 0x6040.Fault
Reset
AL380
Position Deviation Alarm
DI.Alm Reset or P0-01 = 0
AL400
Index coordinates error
Turn DI.ARST on to clear the alarm.
AL401
NMT Reset command is received when
Servo On
Turn DI.ARST on to clear the alarm.
AL404
Value of PR special filter setting is too big
Turn DI.ARST on to clear the alarm.
AL555
System Failure
N/A