Pin Function
1
Digital input 1
2
Digital input 2
3
4
5
6
Digital input 3
Digital input 4
Digital input 5
Output
Cable requirements:
 Conductor cross-section: 0.205 mm² (AWG24) ~ 0.081 mm².(AWG28)
 Outside diameter of cable : 3.8mm ~ 5.2mm
 Please refer to UL 2464 computer cable guideline
Function
Country = Italy & Italy with SPI
No function
Remote off
Narrow
frequency limit.
Note: 1 = Relay is closed, 0 = Relay is open.
Note: 1 = Relay is closed, 0 = Relay is open.
D1
0
1
0
D2
0
0
1
D3
0
0
0
D4
0
0
0
D5
0
0
0
Output
1
1
1
Function
Country = Germany
No function
Active power =
0%
Active power =
30%.
Active power =
60%
Active power =
100%
D1
0
1
0
D2
0
0
1
D3
0
0
0
D4
0
0
0
D5
0
0
0
Output
1
1
1
0
0
0
0
1
0
0
1
0
0
1
1
Country = Australia or New Zealand
#1: Relay is closed, 0: Relay is open.
Function
No function
DRM 0
Disconnection device
DRM 5
Active power = 0
DRM 6
Active power < 50%
DRM 7
Active power < 75%
Sink reactive power
D1
0
1#
0
D2
0
0#
0
D3
0
0
0
D4
0
0
0
Output
1
1
1
0
0
0
0
0
1
1
0
1
1
DRM 8
Active power < 100%
Sink reactive power
0 1 0 0
D5
0
0
1
0
0
0 1
59
Appendix B

Table of Contents

Other manuals for Delta RPI-H5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta RPI-H5 and is the answer not in the manual?

Delta RPI-H5 Specifications

General IconGeneral
BrandDelta
ModelRPI-H5
CategoryInverter
LanguageEnglish

Related product manuals