Installation and Operation Manual
Europe Australia New Zealand
RPI M6A
RPI M8A
RPI M10A

Table of Contents

Other manuals for Delta RPI M6A

Questions and Answers

  • M
    Michelle RobertsSep 7, 2025
    What does HW NTC3 Fail (F09) mean on my Delta RPI M6A Inverter?
    • V
      vbaileySep 7, 2025
      If your Delta Inverter displays HW NTC3 Fail (F09), it means the ambient temperature is >90?or
  • R
    Ruth WarrenAug 25, 2025
    What should I do if my Delta RPI M6A displays AC Volt High (E11, E13, E16, E18, E21, E23)?
    • F
      fguerraAug 25, 2025
      If your Delta Inverter is showing AC Volt High (E11, E13, E16, E18, E21, E23), here's what you can check: * The utility voltage on the inverter terminal may be over the OVR setting. Check the utility voltage on the inverter terminal. * The utility voltage may be over the Slow OVR setting during operation. Check the utility voltage on the inverter terminal. * The country or Grid setting could be incorrect, so check the country and Grid settings. * There might be a detection circuit malfunction inside the inverter, so check the detection circuit inside the inverter.
  • G
    Gloria LeeAug 25, 2025
    What does it mean when my Delta RPI M6A Inverter says No Grid (E09)?
    • A
      Alexander SimonAug 26, 2025
      If your Delta Inverter shows a No Grid (E09) error, it could be due to: the AC breaker being OFF (in this case, switch on AC breaker) or a disconnection in the AC plug (in this case, check the connection in AC plug and make sure it connects to inverter).
  • C
    choweSep 16, 2025
    What does RCMU Fail (F27) mean on my Delta Inverter?
    • J
      Jonathon PetersSep 16, 2025
      If your Delta Inverter displays RCMU Fail (F27), it could be due to: * RCMU is disconnected. Check the RCMU connection inside the inverter. * Detection circuit malfunction. Check the detection circuit inside the inverter.
  • N
    Nathaniel PalmerSep 23, 2025
    How to troubleshoot 'Insulation' error on Delta Inverter?
    • D
      Danielle JimenezSep 23, 2025
      If your Delta Inverter shows an 'Insulation' error, it could be due to: * A PV array insulation fault. * Large PV array capacitance between Plus to Ground or Minus to Ground or both. * A detection circuit malfunction. To troubleshoot, check the insulation of Solar inputs and the capacitance. Dry the PV panel if necessary. If the problem continues, check the detection circuit inside the inverter.
  • Z
    Zachary ReevesSep 12, 2025
    What does HW DSP ADC3 (F17) mean on my Delta RPI M6A Inverter?
    • L
      lisa75Sep 12, 2025
      If your Delta Inverter displays HW DSP ADC3 (F17), it could be due to: * Insufficient input power. Check the input voltage, must >150Vdc. * Auxiliary power circuitry malfunction. Check the auxiliary circuitry inside the inverter. * Detection circuit malfunction. Check the detection circuit inside the inverter.
  • S
    Selena GarciaSep 2, 2025
    What does DC Injection (F01, F02, F03) mean on my Delta Inverter?
    • G
      Gregory OrtizSep 2, 2025
      If your Delta Inverter displays DC Injection (F01, F02, F03), it could be due to: * An abnormal utility waveform. Check the utility waveform. The grid connection of the inverter needs to be far away from non-linear load if necessary. * A detection circuit malfunction. Check the detection circuit inside the inverter.
  • R
    Ryan BeckSep 3, 2025
    What does Ground Cur. (F24) mean on my Delta RPI M6A?
    • S
      Sue Johnson DDSSep 3, 2025
      If your Delta Inverter displays Ground Cur. (F24), it could be due to several reasons: * A PV array insulation fault. Check the insulation of Solar inputs. * Large PV array capacitance between Plus to Ground or Minus to Ground. Check the capacitance (+ GND & - GND), must < 2.5uF. Install a external transformer if necessary. * Either side of boost driver or boost choke malfunction. Check boost driver & boost choke. * A detection circuit malfunction. Check the detection circuit inside the inverter.
  • T
    Timothy JonesSep 23, 2025
    What does 'Solar2 High' mean on a Delta RPI M6A Inverter?
    • J
      Joshua WellsSep 23, 2025
      If your Delta Inverter is displaying 'Solar2 High', it could be due to: * The actual Solar2 voltage exceeding 1000Vdc. * A detection circuit malfunction. To resolve this, adjust the solar array setting to ensure the Voc is below 1000Vdc. If the issue persists, inspect the detection circuit inside the inverter.
  • E
    Erin HannaAug 29, 2025
    What does Solar1 High (E30) mean on my Delta RPI M6A?
    • C
      carriephelpsAug 29, 2025
      If your Delta Inverter displays Solar1 High (E30), it could indicate that the actual Solar1 voltage is over 1000Vdc (in this case, modify the solar array setting, and make the Voc less than 1000Vdc) or a detection circuit malfunction (in this case, check the detection circuit inside the inverter).