83
Installation and Operation Manual for RPI M6A M8A M10A inverters V1.0 2016-02-03
8 Settings
8.12 Max. Power (Maximum feed-in power)
Overview
This function should be set only when requested by country regulations, authorities or your grid operator.
With this function you can limit the maximum active power to be fed into the grid.
Accessing the menu
Main menu > Install Settings > Max. Power
E-Today: 0kWh
Power: 0W
Status: On Grid
10.Sep 2014 15:32
1. When the default information is displayed, press any button to open the main menu. Oth-
erwise, repeatedly press the button
ESC
until the main menu is displayed.
Inverter Info.
General Settings
2. Use the buttons and to select Install Settings.
To conrm your selection, press the button
ENT
.
energy production
Adj. would effect
3. The menu is protected by password 5555. Use the buttons and to set each digit.
To conrm a digit, press the button
ENT
.
AC Connection: 3P4W
EPO: Normal Close
Anti-islanding: ON
Max. Power: 10000W
Return to Factory
4. Use the buttons and to select Max. Power. The current setting is displayed
behind the menu entry.
5. To start editing the parameter value, press the button
ENT
.
6. To change the parameter value, use the buttons and .
To conrm your selection, press the button
ENT
.
To cancel the action, press the button
ESC
.
Congurable Parameters
Parameter Description Value range
Max. Power
Limits the maximum power to be fed into the grid.
0 ... 33000 W
Default: according to the country
regulations
Do not change this setting without prior
consultation with Delta Solar Support.