12 Descriptions of Parameter Settings | VFD-ED
12-02-17
02-40
02-42
Direct Docking Mode Only
Control Mode
VFPG FOCPG FOCPM Default: -
Settings Contact Delta for more information
02-43
Speed Reached Bandwidth
Control Mode
VF VFPG SVC FOCPG FOCPM Default: 2.00
Settings 0.00299.00 Hz
When drive’s output frequency and target frequency is smaller than or equal to this bandwidth, multi-
function output terminal MO=2 and MO=40 will be activated (ON). When drive’s output frequency and
target frequency is larger than this bandwidth, MO=2 and MO=40 will be deactivated (OFF).