EasyManua.ls Logo

Delta VFD-ED Series

Delta VFD-ED Series
447 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Descriptions of Parameter Settings | VFD-ED
12-03-4
This function is only valid for AUI1.
Auto-tuning process:
Reserved
Analog Output Selection 1
Analog Output Selection 2
Control Mode
VF VFPG SVC FOCPG
FOCPM
Default: 0
Settings 0: Output frequency (Hz)
1: Frequency command (Hz)
2: Motor speed (RPM)
3: Output current (rms)
4: Output voltage
5: DC bus voltage
6: Power factor angle
7: Power factor
8: Output torque
9: AUI1
10: Reserved
11: AUI2
12: q-axis current
13: q-axis feedback value
Start
Set
Pr.03-00 = 3
Pr.03-06 = 4
Pr.03-23 = 0
Run (0Hz) the car for more
than 5 seconds without load
Run (0Hz) the car for more
than 5 seconds with larger
than 50% of the load.
Set
Pr.03-15 = 2
Check
Pr.03
-03 Analog Input Bias 1 (AUI1)
Pr.03-09 Analog Input Gain 1 (AUI1)
End
Check ride comfort
YES
NO
Set
Pr.07-13 = 2
Pr.07-19 = 1
Set
Pr.03-15 = 1
Set
Pr.07-19 = 0
When tuning is finished,
Pr.03-15 will become 0.
When tuning is finished,
Pr.03-15 will become 0.

Table of Contents