Chapter 13 Warning Codes | VFD-ED
Display on KPC-CC01 Descriptions
1
CE01
Illegal communication command
Cause
Communication command error
2
CE02
Illegal data address
Cause
Data address error
3
CE03
Communication data length error
Cause
Communication data length exceeds 1–20 characters
4
CE04
Attempt to write to a read-only address.
Cause
Communication error occurred when attempting to
write values into 0x21xx, 0x22xx read-only address.
5
CE10
Modbus transmission time-out
Cause
Communication cable error
6
CP10
CP10
Keypad time out
Warning
Digital keypad KPC-CC01 transmission time-out
Cause
Communication cable or digital keypad error
7
SE1
Keypad copy parameter error
Cause
Keypad copy errors, including communication delays,
communication error (keypad received error FF86)
and parameter value error.
8
SE2
Keypad copy parameter failure
Cause
Keypad copy done but parameter writing error
9
oH1
IGBT overheat warning
Cause
IGBT temperature is over the default 90ËšC (Pr.06-14).
CE01
Comm. Cmd. Err
Warning
CE02
Data Adrr. Err
Warning
CE03
Data Length Err
Warning
CE10
Comm. Time Out
Warning
SE1
Keypad Copy Err
Warning
SE2
Keypad Copy Fail
Warning