Chapter 13 Warning Codes | VFD-ED
Display on KPC-CC01 Descriptions
10
oH2
Capacitor overheat warning
Cause
The temperature of the capacitor is over 65˚C.
15
PGF1
Cause
When Pr.10-03 = 0 (default = 2), a warning message
displays instead of a fault message when an error
16
PGF2
Cause
Pr.10-03 = 0 (default = 2), a warning message
displays instead of a fault message when an error
17
PGF3
PG feedback stall warning
Cause
Pr.10-09 = 0 (default = 2), a warning message
displays instead of a fault message when an error
18
PGF4
Cause
Pr.10-09 = 0 (default = 2), a warning message
displays instead of a fault message when an error
19
PHL
Phase loss
Cause
When Pr.06-01 =0 (default = 2), a warning message
displays instead of a fault message when a phase
loss occurs.
20
ot1
Cause
When Pr.06-05 =1 or 3 (default = 0), a warning
message displays instead of a fault message when
there is an over-torque detection.
21
ot2
Over-torque 2
Cause
When Pr.06-05 =1 or 3 (default = 0), a warning
message displays instead of a fault message when
there is an over-torque detection.
22
oH3
Motor overheat (PTC)
Cause
When Pr.06-26 = 0 (default = 0), a warning message
displays when there is a PTC detection.
oH3
Motor Over Heat (PTC)
Warning