Chapter 11 Summary of Parameter SettingsMS300 (High Speed Model) 
 
11-27
 
Pr.  Explanation  Settings 
Factory 
Setting
 
07-20 
Deceleration of emergency or 
forced stop   
0: Coast to stop 
1: Stop by 1
st
 deceleration time   
2: Stop by 2
nd
 deceleration time 
3: Stop by 3
rd
 deceleration time 
4: Stop by 4
th
 deceleration time 
5: System Deceleration 
6: Automatic Deceleration
 
0 
 
07-23 
Auto voltage regulation (AVR) 
function 
0: Enable AVR 
1: Disable AVR 
2: Disable AVR during deceleration 
 
0 
 
07-24 
Filter time of torque 
compensation  
0.001~10.000 sec.
 
0.050 
 
07-25  Filter time of slip compensation  0.001~10.000 sec.
  0.100 
 
07-26 
Torque compensation gain  IM: 0~10   
0 
 
07-27 
Slip compensation gain    0.00~10.00 
0.00 
 
07-32 
Motor shock compensation 
factor 
0~10000
  1000 
 
07-33 
Return time of fault restart  0.0~6000.0 sec.
 
60.0 
 
07-62 dEb gain  0~65535 
4000 
 
07-71 
Torque compensation gain   
(motor 2) 
IM: 0~10    0 
 
07-72 
Slip compensation gain   
(motor 2) 
0.00~10.00 
0.00 
 
07-73 
Torque compensation gain   
(motor 3) 
IM: 0~10 
0 
 
07-74 
Slip compensation gain   
(motor 3) 
0.00~10.00 0.00 
 
07-75 
Torque compensation gain   
(motor 4) 
IM: 0~10 
0 
 
07-76 
Slip compensation gain   
(motor 4) 
0.00~10.00 
0.00