NO.6 Detailed Function Description
53
P085 is a selection for the acceleration/deceleration time of last 8 segments (calculation
method is the same as that for P084).
P086
Setting Range
Unit
Ex-factory Value
Alteration
Frequency II setting
0.00-400.00 Hz
0.01
Hz
15
P087
20
Frequency III setting
P088
25
Frequency IV setting
P089
30
Frequency V setting
P090
35
Frequency VI setting
P091
40
Frequency VII setting
P092
0.5
Frequency VIII setting
P093
10
Frequency IX setting
P094
15
Frequency X setting
P095
20
Frequency XI setting
P096
25
Frequency XII setting
P097
30
Frequency XIII setting
P098
35
Frequency XIV setting
P099
40
Frequency XV setting
P100
45
Frequency XVI setting
The parameter can be set, combining multi-function input terminals, with externally controlled
4-segment speed, externally controlled multi-segment speed and internally controlled multi-
segment speed selectable. Refer to P080 and P086-P100 description for details about
related parameters.