Denlar D100 - Common Parts List

Default Icon
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D1000 Installation and Service Manual 36
Home LAB-110073 Rev. 3
D1000 COMMON PARTS LIST
Model Description
D1030-F
30-Inch-Wide - Front Vented, Recirculating Design, 18 GA, 304 Stainless Steel Hood with Internal Fan, PLC Environmental Monitoring & Fire
Suppression System
D1030-R
30-Inch-Wide - Rear Vented, Rear Duct Connection, 18 GA, 304 Stainless Steel Hood with Internal Fan, PLC Environmental Monitoring & Fire
Suppression System
D1030-D***
30-Inch-Wide - Top Vented, Vertical Duct Connection, 18 GA, 304 Stainless Steel Hood with External Fan, PLC Environmental Monitoring &
Fire Suppression System
D1036-F
36-Inch-Wide - Front Vented, Recirculating Design, 18 GA, 304 Stainless Steel Hood with Internal Fan, PLC Environmental Monitoring & Fire
Suppression System
D1036-R
36-Inch-Wide - Rear Vented, Rear Duct Connection, 18 GA, 304 Stainless Steel Hood with Internal Fan, PLC Environmental Monitoring & Fire
Suppression System
D1036-D***
36-Inch-Wide - Top Vented, Vertical Duct Connection, 18GA, 304 Stainless Steel Hood with External Fan, PLC Environmental Monitoring &
Fire Suppression System
External Fan for “D1000-D” Ducted Models and NFPA upgrades
IF D1000 Only – 10” Inline Fan and 35 Foot Cable
WF D1000 Only – Exterior Wall Mount Fan with 35 Foot Cable
RF D1000 Only – Roof Mounted Fan with 50 Foot Cable
F (R)-NFPA D1000-F (R) - Upgrade to NFPA Life Safety Code with Internal Fan
IF-NFPA D1000-D-IF – 12” Inline Fan and 35 Foot Cable with Upgrade to NFPA Life Safety Code
WF-NFPA D1000-D-WF – Exterior Wall Mount Fan with 35 Foot Cable with Upgrade to NFPA Life Safety Code
RF-NFPA D1000-D-RF – Roof Mounted Fan with 50 Foot Cable with Upgrade to NFPA Life Safety Code
Range Element Disconnect
D1000-E Electrical Disconnect Box * [required - which NEMA is needed, 120V 5-15, 5-20, 220V 6-20 or 14-50]
D1000-G 3/4” NPT Solenoid Gas Valve 120VAC
D1000-DED
Dual Element Disconnect Integrated 'E' and 'G' * [required if electric Igniters need to be powered] [required - which NEMA is needed, 120V 5-
15, 5-20, 220V 6-20 or 14-50]
D1000-DRD Dual Receptacle Disconnect 2-120VAC (5-15 or 5-20) or 2 -220VAC (6-20) Receptacles * [required - which NEMA is needed?]
Optional Components
CLBX The “ClockBox” - password protected, range element time out system
D1000-ADA Handicap Accessible Control Box Includes wiring harness, light and fan controls
D1000-MPK Manual Pull Kit, Face Plate, 3 Elbows, 25 Foot Cable
D1000-LSC
Limiting speed control module to limit maximum CFM’s exerted by the fan
D1000-FBO Control Module to allow the use of a fan not provided by DFP, see data sheet for details
D1000-MACM Make-up Air Control Module External to energize a separate Make-Up Fan (not provided), limited to 10 Amps
D1000-STROBE Horn & Strobe Light, designed to be used in conjunction with the D1000
D103X-TC-D Top Cover for D1030/D1036 Ducted “D” Models
D103X-TC-F (R) Front / Rear Vented Top Cover for D1030/D1036 Model (not compatible with NFPA101)
Test Kits & Spare Parts
D1000-TANK-FC D1000 Replacement Kit Tank Assembly, Fully Charged [cannot ship via Air]
D1000-TANK-
TEST
D1000 Test Kit Tank Assembly, Nitrogen only with Adapter & Test Link [cannot ship via Air]
D1000-TANK-SA D1000 Replacement Kit Tank Assembly with Suppression Agent with Adapter but unpressurized [requires Nitrogen charge]
D1000-TANK-E D1000 Replacement Kit Tank Assembly without Suppression Agent with Adapter / Unpressurized [requires Nitrogen charge]
D1000-TEST-KIT D1000 Test Kit (Set of 2 Test Links, 5 Nozzle Caps and 1 Safety Key & Pin)
D103x-ASK D1030= 212 ⁰F or D1036=280⁰F- Annual Service Kit (3 Links & 1 Service Tag)