[Precautions for Disassembly]
When disassembling, connect the F102 and GND with an ground lead, and discharge for approximately 10 seconds before
starting the disassembly.
1. FRONT PANEL ASSY
Proceeding : TOP COVER
→
FRONT PANEL ASSY
(1) Remove the screws.
(2) Remove the connector wires and the FFC. Remove the screws.
Ground wire
GND
F102
View from the bottom.
CP200
FFC
See "EXPLODED VIEW" for the disassembly method of each P.C.B included in FRONT PANEL ASSY.