21
7. "DPMS" force update mode
Update the rmware of DPMS.
Operation
Hold down buttons "SOURCE" button and "CURSOR
1
" button at the same time and connect the power cord to an outlet.
See
"PROCEDURE FOR UPGRADING THE VERSION OF THE FIRMWARE"
.
Error code table
• Preparation operation rewritten, Update error code checking.
ErrCode DPMS Update
Hex The occurred event FL Message
01 Login failed
(
DPMS Access Login Incorrect notication
)
Login failed 01
02 Login failed
(
DPMS Access Server Busy information
)
Server is busy 02
03 Login failed
(
DPMS Access link failure information
)
Connection fail 03
04 Firmware Individual information acquisition failure Connection fail 04
05 Firmware Individual information acquisition TimeOut Connection fail 05
06 Firmware all information acquisition failure Connection fail 06
07 Firmware all information acquisition TimeOut Connection fail 07
08 Error notication received at the time of Firmware Info request Connection fail 08
09 Firmware Info response acquisition Time Out Connection fail 09
0A Firmware Down Load failed
((
NG
)
information recieved
)
Download fail 0A
0B Firmware Down Load failed
((
ServerBusy
)
information recieved
)
Download fail 0B
0C Firmware Down Load failed
((
Connection failed
)
information recieved
)
Download fail 0C
0D Received Package Version is wrong Connection fail 0D
20 Transition to the Boot Loader Mode
(
Failure to acquire the IP Address
(
AutoIP
))
Connection fail 20
21 Transition to the Boot Loader Mode
(
Failure to acquire the IP Address
(
TimeOut
))
Connection fail 21
22 Transition to the Boot Loader Mode
(
DDPMS Access Login Incorrect notication
)
Login failed 22
23 Transition to the Boot Loader Mode
(
DPMS Access Server busy infomation
)
Server is busy 23
24
Transition to the Boot Loader Mode (DPMS Access connection failed i nformation
recived
)
Connection fail 24
25 Transition fails to Boot Loader Mode Connection fail 25
27 Write failure to the Boot Loader Mode to transition after the EEPROM Connection fail 27
• Firm error codes at the main microprocessor rewritten.
ErrCode DPMS Update
Hex
The occurred event
FL Message
10
Firm Info response acquisition Time Out (Main rewrite Firmware recived failure (Time
Out))
Updating fail 10
11
Firm Info response acquisition recived error (Main rewrite Firmware recived failure (Error)
Updating fail 11
12
Firm Info response acquisition recived error (Main rewirte Firmware recived data incorrect
(Check Sum Error))
Updating fail 12
13
Rewrite failure (Block Erase failued before Main rewriting )
Erase fail 13
14
Rewrite failure (Block Write failued before Main rewriting)
Updating fail 14
15
Rewrite failure (Verify incorrect after Main rewriting)
Updating fail 15
22
Transition to the Boot Loader Mode (DPMS Access Login Incorrect notication)
Login failed 22
23
Transition to the Boot Loader Mode (DPMS Access Server busy infomation)
Server is busy 23
24
Transition to the Boot Loader Mode (DPMS Access connection failed infomation)
Connection f ail 24
39
Login failure (DPMS Access access Time Out)
Connection f ail 39
3A
Down Load failure (Download error (NG)information recieved)
Download fail 3A
3B
Down Load failure (Download error (Server Busy) information recieved)
Server is busy 3B
3C
Down Load failure (Download error (connection failed)information recived)
Connection fail 3C
3D
Transition to the Boot Loader Mode (Failure to acquire the IP Address (Auto IP))
Connection f ail 3D
3E
Transition to the Boot Loader Mode (Failure to acquire the IP Address (Time Out))
Connection f ail 3E
3F
Fail in moving into Boot Loader Mode.
Connection fail 3F
• CX920 error codes when rmware rewriting.
ErrCode DPMS Update
Hex The occurred event FL Message
A0 Failure to acquire the IP Address
(
AutoIP
)
Connection
f
ail A0
A1 Failure to acquire the IP Address
(
TimeOut
)
Connection
f
ail A1
A2 Login failed
(
DPMS Access Login Incorrect notication
)
Login failed A2
A3 Login failed
(
DPMS Access Server busy infomation
)
Server is busy A3
A4 Login failed
(
DPMS Access connection failed infomation
)
Connection
f
ail A4
A6 Error notication received at the time of Firmware Info request Updating fail A6
A7 Firmware Info response acquisition Time Out Updating fail A7
AE Down Load failure (Download error (NG)information recieved) Download fail AE