79
Barcode Handy Terminal
“8: STF”: Detail setting of the standard 2of5 (STF) reading
1. Selec
Th
“1
Point Always set the minimum number of digits to a number less than the maximum number o
t “2: STF” at the SET BARCODE menu and then press the ENT key.
e SET STF screen appears.
: MIN”:
Sets the minimum number of the STF digits.
Setting range:
1 to 99
“2: MAX”:
Sets the maximum number of the STF digits.
Setting range: 1 to 99
f
digits. If the minimum number exceeds the maximum number, a read error occurs.
“3: CD CHECK”:
Reading is carried out only if the check digit is correct. Reading is not carried out if either
“OFF”: Reading is carried out regardless of the presence of the check digit.
“BOT g of both normal and short types.
“NORMAL”: Enables reading of the normal type.
select the desired item.
4. Press the ENT or Backspace/clear key to update the setting and return to the SET BARCODE
menu.
“ON”:
the check digit
is incorrect or does not e
xit.
“4: TYPE :
H”: Enables readin
“SHORT” : Enables reading of the short type.
2. Use the cursor keys ([] []) or numeric keys ([1] [2] [3] [4]) to
3. Press the cursor keys ([] []) to select the desired setting.