Numbers of
lamps turned - on
Color of lamps
DCA-25USI
DCA-25USI2
DCA-45USI
DCA-60USH
DCA-4 5USI2
Fuel level
(L)
Fuel level
CL)
Fuel level
(L)
Fuel level
(L)
6
all green
80 to full
70 to full 140 to full 125 to full
5 all green
70 to 75
60 to 70 120 to 140
100 to 125
4 all green
60 to 70
50 to 60 100 to 120
75 to 100
3
red on 1st lamp from
bottomgreen on
2nd & 3rd lamps
45 to 60 35 to 50 75 to 100
45 to 75
2
all red
30 to 45
25 to 35
50 to 75 25 to 45
1 red
0 to 30
0 to 25
0 to 50 0 to 25
(3) Alarm and Memory at Abnomal Condition
When any abnormal condition occurs in engine oil pressure, battery charging voltage,
or engine coolant temperature, the indication will change as the followings ;
- 1 - The indication changes to " AUTO " , and the abnormal value and unit will
be indicated lighting on and off.
- 2 - When the abnormal condition is corrected, the on - and - off indication will
stop.
- 3 - If engine would stop urgently and automatically or stop manuslly with
the abnormal condition, the abnormal value will be memorized, and then
indicated even after engine is started again.
In this case, keep on pushing the button " AUTO " for more than 5 seconds,
and the abnormal indication will be reset to normal.
I
Generator indicators
(1) Frequency meter
This meter indicates frequency of the output
voltage.
Make sure that it indicates 50Hz or 60Hz during
operation.
ф ® S p
ф 5s
'X \ ' Л К / A
V
7
A-
e ®
Ф 0
0 0
...
_i
50Hz 60Hz
-