5 -4 Shut down
(1) Turn OFF the circuit breaker of the load. circuit breaker of the load
(2) Turn OFF the circuit breaker of the machine.
(3) Set the throttle lever in "START / IDLING"
position and put the machine in cooling operation
for about 5 minutes.
(4) Set the starter switch in "STOP" position.
The engine will stop immediately.
(5) Remove the key from the starter
switch and keep it at hand.
(6) Check the pannel light goes out.
(7) The 25USI unit has a fuel cock at the bottom of the
fuel tank. After engine is shut down, turn the cock
sideways to "CLOSE".
(8) Check the amount of fuel. Supply
additional fuel if necessary.
circuit breaker of the machine
cooling operation for about 5 min,
I
throttle lever
C r ^ '
starter switch
(9) Check for leakage of oil, fuel and
water.
[Note]
For emergency stop, keep pushing
the "EMERGENCY STOP" button
until the engine stops.
-
44
-