- 19 -
E
2-2 Transportation
When lifting or transporting the machine, use only appropriate devices which comply with
the local safety codes and regulations.
For dimensions and weight of the machine, refer to “7 Principal Data”.
See Fig 5 for the center of gravity.
Fig. 5
Model L W H
DCA-70ESEI 1350 500 710
DCA-125ESEI 1790 570 770
DCA-180ESEI 2050 600 750
When lifting the machine, use the hanger located at the roof center.
Never use the rope hanger because it is not strong enough to lift.
Before lifting, close and fix the doors, covers, and other moving parts and clear away the
machine interior and top.
Do not slip under a lifted machine.
Before transporting by truck or others, wind ropes on the machine to fasten it securely.
Put covers so as to protect the machine from rain or moisture when transporting.
2-3 Storage
2-3-1 Storage method
1. Store the generator in a sufficiently ventilated, dry room which is free from frost, salt and dust.
Storage environment: Atmospheric temperature -5 to 40°C, humidity 85% or lower, altitude
1000m or lower.
2. Run the engine once a week until warm.

Table of Contents