- 21 -
E
2-4 Installation
2-4-1 Installation
1. Install the generator on a well ventilated, horizontal, even and solid floor. If the floor is not
horizontal enough to keep the machine leveled, consult your sales distributor. When installing
the machine on a trailer, fasten the trailer and fix the wheels by stoppers. Avoid a site exposed
to rain or high temperature. The operating ambient conditions are atmospheric temperature of
-5 to 40°C, humidity of 85% or lower and altitude of 1000m or lower. If the machine do not
conform with the above conditions, consult your sales distributor.
2. Avoid a dusty site. If it is inevitable, provide protective devices.
3. Do not operate the machine in an atmosphere containing toxic or combustible gas. Otherwise
fire or explosion might occur in the machine. (Example: Near volatilizing paint solvent.)
4. Leave space for operation, inspection and maintenance; at least 500 mm each on machine front
and 1000 mm each on rear and sides. See Fig. 6
Fig. 6
[ NOTE ]: If the machine is operated in a smaller space than that shown above, the room
temperature will rise. Please reduce the generator output in such condition.
Therefore proper power reduction is necessary.
If the space required above the machine is not uniform when it is operated indoors, make a
decision so that:
• The radiator can be refilled with cooling water.
• The exhaust pipe can be introduced.
• The exhaust can smoothly be discharged.