EasyManua.ls Logo

Desoutter CONNECT-X - Page 73

Desoutter CONNECT-X
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN Troubleshooting
03/2020 73 / 84
Number Description Procedure
I199 Console activated 1- The serial console is activated.
2- Warning: this console is dedicated to debug pur-
poses only and should not be used in production.
I202 Fieldbus lost 1- Fieldbus connection with PLC is lost.
- no heartbeat is received from PLC.
- the cable is broken or disconnected.
- the PLC is offline or not powered.
2- Check the Fieldbus configuration.
I204 Tool not validated 1- Tool locked by I/O.
2- Check I/O settings: "Tool validation" must be active
to unlock the tool.
I207 Assembly done 1- Assembly Process is done, the tool is locked.
2- Select a new Assembly Process to unlock the tool.
I208 Invalid run reverse parameter 1- Invalid Run Reverse setting: torque or speed are
greater than tool characteristics or loosening strategy is
not supported.
2- Check Pset settings with the current tool characteris-
tics.
3- Reduce the maximum number of turns.
I209 Pset invalid parameters 1 - Software internal error.
2 - Pset is corrupted. Try to transfer it again to the sys-
tem.
3 - If the error persists, contact your Desoutter repre-
sentative for support.
I215 Current calibration error 1- Current calibration failed.
2- Try once again.
3- If the problem occurs again, contact your Desoutter
representative for support.
I225 Error angle 1- Tool communication error.
2- Check tool and cable connections.
3- If the problem occurs again, contact your Desoutter
representative for support.
I226 Error torque 1- Tool communication error. Check tool and cable
connections.
2- Try once again.
3- If the problem occurs again, contact your Desoutter
representative for support.
I234 Fieldbus mismatch 1-The Fieldbus module declared in configuration is not
the same than the module connected to the system.
I237 Invalid data 1- The Fieldbus mapping has too many items.
I238 Invalid address 1- The device address affected to Fieldbus is invalid.
I239 Invalid communication settings 1- Fieldbus communication settings are invalid.
I241 CVINET FIFO alarm 1- CVINET FIFO has reached the alarm threshold, the
connection is lost.
2- Check the Ethernet cable.
3- Check the Ethernet configuration.
4- Check that CVINET is running correctly.
I242 ToolsNet FIFO alarm 1- ToolsNet FIFO has reached the alarm threshold, the
connection is lost.
2- Check the Ethernet cable.
3- Check the Ethernet configuration.
4- Check that ToolsNet is running correctly.
I244 Accessory disconnected 1- The accessory at the given address has been discon-
nected from the eBUS of the system.
2- Check the accessory cable.
I245 Wait report acknowledge 1- Acknowledge report with its corresponding input.

Table of Contents

Related product manuals