21
5. LED Indicators
LED
Description
Description
Power LED
• Not Illuminated: The charge point is powered off
• Solid Green: The charge point is powered on
• Flashing Yellow: Data is being transmitted and/or firmware is
upgrading
• Solid Yellow: Firmware upgrade has failed
• Solid Blue: Data transmission has failed; will illuminate green in five
seconds
Internet
Connection
LED
• Not Illuminated: The charge point is not connected to the backend of
the charging management system.
• Solid Green: The charge point is connected to the internet
• Flashing green: The charge point has joined the DLB (Dynamic Load
Balancing) network
Charging LED
• Not Illuminated: The charge point is not connected
• Solid Blue: An EV is connected
• Flashing Blue: A schedule is active
• Flashing Green: An EV is charging
• Solid Green: A charge session has ended
• Solid Yellow: A recoverable error has occurred or the product is
temporarily disabled by the cloud server
• Solid Red: An irrecoverable error has occurred (please contact
technical support)
Bluetooth
Connection
LED
• Not Illuminated: The charge point is not connected via Bluetooth
• Flashing Green: The charge point is connected to a mobile device via
Bluetooth.