8514-265-001 REV C PAGE 2
TABLE OF CONTENTS
Page No.
Warnings about use and operation 2
Dryer Specifications 3
Dryer Dimensions 6
Installation Instructions 12
Dryer Shutdown 17
Description of Dryer Control 18
Dryer Fault Codes 19
Operating Instructions 23
Programming the Dryer Control 24
Servicing and Troubleshooting 30
Preventative Maintenance Instructions 31
WARNINGS ABOUT USE AND OPERATION
DO NOT MODIFY THIS APPLIANCE. KEEP SHIELDS, GUARDS, AND COVERS IN PLACE. These
safety devices are provided to protect everyone from injury.
It is ABSOLUTELY ESSENTIAL that the dryer be grounded to a known earth (zero) ground in accordance
with local codes or, in the absence of local codes, with the latest editions of the National Electric Code, ANSI//NFPA
70 or Standard CSA C22.1 Canadian Electrical Code Part 1. This is not only for personal safety, but is necessary
for proper operation of the controller. Failure to do so will void the warranty of the controller.
THIS DRYER IS EQUIPPED WITH AN OVER-TEMPERATURE THERMOSTAT located above the
motor on the side of the exhaust duct. If the dryer ceases to operate, refer to your “Service Procedure and Parts
Data” book for instructions.
CHECK THIS THERMOSTAT WHEN INSTALLING DRYER to assure it is not tripped. Impacts such as
rough handling in shipment, may trip the thermostat. It may be reset by inserting a wooden pencil or dowel
through the bushing in the cover.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE while in operation.
THIS APPLIANCE SHALL NOT BE USED TO DRY OFF SOLVENTS OR DRY-CLEANING FLUIDS.