8514-296-001 REV K page 84
Solution Check VFD light code before turning off
power. Turn the power off to the washer.
Check the wiring connections to the S1,
S2, and +24V drive jumper connections.
If no problem is observed, turn on power
to the washer and test. If problem
reappears, contact your Dexter
representative.
DRIVE_PHLI VFD Input Phase
Loss
Condition This error occurs when an input phase
loss is detected
Delay Occurs following the “DELAY” error (see
corresponding detail)
Action
Stop the machine and clear the cycle.
Keep the door locked until the machine
has stopped moving and then unlock the
door.
Solution Check VFD light code before turning off
power. Turn the power off to the
Check the wiring connections to the drive
and motor. If no problem is observed,
turn on power to the washer and test. If
problem reappears, contact your Dexter
representative.
DRIVE_PHLO VFD Output Phase
Error
Condition This error occurs when an issue is
detected with the drive output phases
Delay
Occurs following the “DELAY” error (see
corresponding detail)
Action
Stop the machine and clear the cycle.
Keep the door locked until the machine
has stopped moving and then unlock the
door.
Solution
Check VFD light code before turning off
power. Turn the power off to the washer.
Check the wiring connections to the drive
and motor. If no problem is observed,
turn on power to the washer and test. If
problem reappears, contact your Dexter
representative.
MOTOR_OL
VFD Motor
Overheating
Condition
This error occurs when the VF AC motor
drive is overheating
Delay Occurs following the “DELAY” error (see
corresponding detail)
Action
Stop the machine and clear the
Keep the door locked until the machine
has stopped moving and then unlock the
door.