Bath Bath Cycle
Time (min.)
Water Temp Delay Fill Spin Time (min.)
Prewash 0
n/a n/a
0
Wash 1 Hot On 2
Extended Wash 0
n/a n/a n/a
Rinse 1 Cold On 0
Final Rinse 0 Cold On n/a
n/a n/a n/a 0
Extra Rinse Bath 0 n/a n/a n/a
Final Extract Spin n/a n/a n/a 4
OPTIONAL_
CYCLES
QUICK_TEST
RAPID_ADVANCE
FINAL_RINSE_
AND_SPIN
Optional Cycles Option:
This option allows the user to select the dierent test and short-cycle options.
Figure 3
Quick Test Option:
When the Quick Test Option is chosen, the washer will begin a shortened wash cycle without the displayed
vend price being met. The purpose of this shortened cycle is to test all major components for proper opera-
tion.
Error Codes should all function normally during this test. The display will show customer prompts in a
similar way to a normal wash cycle. Exceptions to this are that the “ADD BLEACH” prompt will not occur
because of reduced cycle time. Final Extract speed is specic to the customer’s programming.
Rapid Advance Option:
Similar to the Quick Test, when the Rapid Advance Option is chosen, the washer will begin a wash cycle
without the displayed vend price being met. However, in this case, it will be a normal default cycle with an
additional feature available. The “START” button LED will ash, prompting the user that, when pressed, the
washer shall rapid advance to the next step in the cycle. The display will show “ADVANCE” when the cycle
is advancing. The water level needs to be empty before this advance occurs. During the time waiting for
the tub to empty, the “ADVANCE” prompt will be held on the display and the START pushbutton LED stops
ashing. The Rapid Advance shall allow the tub to empty of water and the tub to stop before beginning
either spin or the next bath.
The Rapid Advance mode can be exited by pressing the programming button. This will end the cycle.
When the Rapid Advance mode is used, the cycle time will no longer be correct. By skipping steps with
Rapid Advance, the door may not open immediately at the end of the cycle.
38