Drive Motor Inverter Type
Motor-Winding Resistance Chart
T-675 O-Series Express Washer
Resistance
Motor Winding Wire # Minimum Maximum
T-675 1PH or 3PH 60Hz Main (wash & spin) T1 & T2 2.58 2.58
Dexter #9376-308-001 T2 & T3 2.58 2.58
T1 & T3 2.58 2.58
T-975 O-Series Express Washer
Resistance
Motor Winding Wire # Minimum Maximum
T-975 1PH or 3PH 60Hz Main (wash & spin) T1 & T2 0.47 0.47
Dexter #9376-326-001 T2 & T3 0.47 0.47
T1 & T3 0.47 0.47
T-1475 O-Series Express Washer
Resistance
Motor Winding Wire # Minimum Maximum
T-1475 1PH or 3PH 60Hz Main (wash & spin) T1 & T2 0.327 0.327
Dexter #9376-328-001 T2 & T3 0.327 0.327
T1 & T3 0.327 0.327
NOTE: Resistance values are measured at the stator. Values at the end of the motor wir-
ing harness may be slightly higher.
55
Part # 8533-126-001 11/21
55