3.3.1 Using a Web browser to modify the Gryphon’s TCP/IP parameters
You may access the hardware configuration pages via a forms-capable browser (like Netscape, IE,
or Lynx) on a network-connected computer. Please note
: this option requires that the current TCP/IP
parameters allow communication over the network. If communication over the network is not
possible (as is often the case when reconfiguration is required), then the TCP/IP parameters must be
changed either through the method described in section 3.3.1, or that described in section 3.3.2.
1. Verify that your PC’s TCP/IP settings do NOT match those set for the Gryphon
®
unit. (The
Gryphon’s default parameters are IP Address = 192.168. 1 . 1 , Netmask = 255.255.255. 0 .)
2. Start your Web browser. Type the following URL: http://192.168.1.1 The following Web
page, with its six areas for viewing (System Administration, Modules/Pinouts, Gryphon
®
Stats,
Channels/Stats, Documentation and Dearborn Group), appears as shown below.
3. Next, click on System Administration. Once you enter this section, a box will prompt you for a
user name and password. The default user name is sysadmin; the default password is
dgGryphon. (Note
: this password is the same as the default root password.)