EasyManua.ls Logo

digicon CATRAX Plus - 7.2 Defects and Possible Causes

digicon CATRAX Plus
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
7.2 Defects and possible causes
Defect
Posible cause
Action
· CATRAX Plus will not
tun on
· The power supply cable is not connected
properly
· The fuse of the power supply is blown
· Check the cables and the
fuse (fuse: 3 A)
· CATRAX Plus locked · Optical sensors obstructed or defective · Perform the preventive
routine maintenance on the
sensors or forward the
equipment to the Technical
Assistance
· A CATRAX Plus does
not activate the
electromagnet
(turnstile cannot be
locked)
· The cable is broken or the distance
between the electromagnet and the
locking device is maladjusted
· Adjust the electromagnet or
forward the equipment to the
Technical Assistance
· The arm does not
remain in the correct
position
· There is wear, dirt, a broken spring or
lack of lubrication in the sphere base
· Request a replacement for
the faulty part or forward the
equipment to the Technical
Assistance
· CATRAX Fit does not
lock in the first tooth
· The distance between the electromagnet
and the locking device is maladjusted
· Adjust the electromagnet or
forward the equipment to the
Technical Assistance
plus