No connection: Check if all connections  are properly made. 
Source off: Check if the equipment is powered on.
Lamp dead:  The lamp  may  need replacement.  Check the  LAMP  TIME in  the  UTILITIES sub 
menu.
Source hibernated: Engage the source to display and activate image.
Notebook external screen: Different notebook PC’s use different combinations of keystrokes 
to enable the external graphics port.
No lens: Check if lens is attached properly.
Shutter engaged: Check if the shutter is engaged.
Lens cap: check if the lens cap is off!
 
DARK IMAGE
Old, worn lamp: The lamp may need replacement. Check the LAMP TIME in the LCD.
Low BRIGHTNESS and CONTRAST settings: Press AUTO or use the menu system, PICTURE 
sub menu for CONTRAST and BRIGHTNESS adjustment.
FLICKERING IMAGE
Bad lamp: Replace the lamp. Check the LAMP TIME in the LCD. 
UNSHARP IMAGE
Keystone correction may have been activated inadvertently, compressing parts of the image that 
affect the display of fine-line graphics, text and other images of high resolution. 
Source resolution is different from projectors native resolution: 
The  projector  will  automatically  scale  and  resize  the  input  format  to  its  native  resolution. 
Use  a  different scaling  factor in  the  PICTURE  sub menu,  ASPECT.  You may  also  adjust  the 
SHARPNESS.