62 EDXtreme User Instructions
11 Specifications
11.1 Dynamometer Specifications
Enclosure: Designed to NEMA4X/IP55. Suitable for continuous outdoor use.
Accuracy: 0.1% of capacity up to EDX-50T.*
0.3% of capacity for EDX-75T and above.*
Repeatability: 0.1% of capacity up to EDX-50T.*
0.3% of capacity for EDX-75T and above.*
* Normal resolution mode with Dillon provided shackles.
Proof Load: 150% of capacity up to EDX-75T.
110% of capcity EDX-100T and above.
Ultimate Overload: See table on page 64.
Safe Overload: 200% of capacity
Body Protection: Aluminum and alloy steel capacities are powder coated.
Bearings: Unmatched repeatability attained by needle bearings in shackle pin holes up to EDX-5T.
Shackle pin acts as inner race.
Shackles: Forged industry standard anchor shackles. Models up to EDX-5T use precision machined
shackle pin. Higher capacities use bar stock pin.
Display: 128 x 64 dot-graphic LCD display shows up to 6 digits 1.0” (26 mm) high plus annunciators and
softkeys. Digits are .11 inches (3 mm) thick for unmatched readability.
Display Update Rate: 2 times per second.
Peak Capture Rate: 10/100/1,000 Hz
Connector: Recessed sealed connector may be used for serial communications or connection to a
Communicator II remote.
RS-232
Communication:
Print or extract data easily. Continuous output can drive a scoreboard. Configurable poll
character.
Calibration: Traceable to the National Institute of Standards and Technology. Certificate included with curve
of readings. Passes only with three consecutive confirming runs, with all points in specification.
Battery Life: Stand alone EDXtreme with no radio and no backlight lasts up to 400+ hours. 40 hours
continuous with Radio Link System. Use with two C-Cell alkaline batteries. (When using
backlight, battery life will be reduced, depending on intensity.)
Operating
Temperature:
-4° F to 158° F (-20° to 70° C)
Included with
Instrument:
All include certificate of calibration, manual and batteries. Plastic carry case included for EDX-
1T to EDX-50T. Higher capacities include rugged plywood storage crate. Instruments with
shackles include centering spacers (EDX-20T & up) and shackle storage crate (EDX-20T to
EDX-75T). Display backlight.
Options: Shackles. Radio communications.