onaregularbasiswhen
theheaterisoperating.
Additionalappliancesonthe
same circuit may exceed the
current rating of the circuit
breaker.
WARNING: To prevent
personalinjuryyoushouldhire
a professional to cap the
chimneyueorcutaholein
theexistingreplaceforwiring.
Ifyoureturnyourexisting
replacetoitsoriginaluse
(examplewoodburning),it
shouldbeinspectedbythelocalbuildingdepartmentpriortouseto
reducetheriskofreandpersonalinjury.
New Wall Construction (Figure4)
1. Selectasuitablelocationthatisnotsusceptibletomoistureandis
awayfromdrapes,furnitureandhightrafc.
!
NOTE: Thereplaceinsertmustbeinstalledonahardsurface.
2. Placethereplaceinthedesiredlocationtoseehowitwilllookin
theroom.
3. Markthedesiredlocationontheoorandstorethereplaceina
safe,dryanddustfreelocation.
4. Usestudstoframeanopeningof26½incheswideX23inches
high(67.3cmwideX58.4cmhigh)allowingadepthof12inches
(30.5cm)(Figure4).
5. Planyourelectricalpowersupply(refertoNOTE1).
Option #1 -Thepowercordcanbeleadfrombehindthetrimand
alongthewalltoanoutletnearthereplace(Figure5).
Option #2 -Anewoutletcanbeinstalledinsidethenewframe
construction(ifallowedbyelectricalcode)(Figure6).