10
4.6 CHECK WEIGHING FUNCTION
This indicator is fitted with check weighing function, which allows the users to set high and low limits. In this way it is
possible to check quickly if the weight is within the range set.
a. The indicator is on, as well as Zero and Stable indicators.
b. Press and hold MODE, until display shows CHK W.
c. Press MODE to enter. The display shows Hi, for high limit setting. Press ZERO for value increment, and TARE for
shifting digits. Press MODE to confirm and enter the low limit setting.
d. Display shows LoW to enter low limit setting. Press ZERO for value increment and TARE for shifting digits. Press
MODE again to confirm and enter alarm setting.
e. The display shows bEEP first, and then bb-no. Press ZERO for options bb-Go, bb-H.L, bb-Hi, and bb-Lo.
Alarm activates when weighing result
activates when weighing results
Alarm activates when weighing result
NOTE:
1. Check weighing function can be engaged under any weighing process, including piece counting mode. When the
weighing unit is PCS, and the check weighing mode is activated, the display shows CHK P for checking piece.
2. If check weighing limits have been programmed before, the display shows PrEV when entering the setup, meaning
that all the previous settings are saved. Press MODE to confirm them, or ZERO to set new limits.
3. To temporary disable the check weighing function, press and hold MODE again to the enter check weighing setup.
Then press ZERO when the display shows CHK W.