5. FUNCTION DEFINITION
5.1 AUTO POWER OFF
With this function, the user can select auto power off time among 5 minutes, 10 minutes, 15 minutes and 20 minutes or
disable the function.
a. The indicator is off.
b. Press and hold TARE, and press ON/OFF; the display shows Fn1.
c. Press TARE until the display shows Fn7.
d. Press MODE to enter. The display shows 5.oFF or previously active option.
e. Press ZERO to select the desired setting. There are 5 settings; the numerical digit represents the minutes to power off,
when the indicator is not used. ALL.on means the indicator will never automatically turn off without manual
intervention.
f. Press MODE to confirm and exit the current function. The display shows Fn8.
g. Press MODE to enter the next function, or press ZERO to exit. When ZERO is pressed, the display shows SAVE. The
user can press MODE (to save the changes made) or ZERO (to exit without saving).
5.2 BACKLIGHT TIMING
With this function, the user can select when to turn off backlight.
a. The indicator is off.
b. Press and hold TARE, and press ON/OFF; the display shows Fn1.
c. Press TARE until the display shows Fn8.
d. Press MODE to enter. The display shows bL.10 or previously active option.
e. Press ZERO to select the desired setting. There are 3 settings; bL.on (always on), bL.oFF (always off) and bL.10 (the
backlight will automatically turn off after 10 seconds, when the indicator is not used).
f. Press MODE to confirm and exit the current function. The display shows Fn9.
g. Press MODE to enter the next function, or press ZERO to exit. When ZERO is pressed, the display shows SAVE. The
user can press MODE (to save the changes made) or ZERO (to exit without saving).
5.3 BUZZER SOUND
Under this function, the user can enable or disable the buzzer sound.
a. Indicator is off.
b. Press and hold TARE, and press ON/OFF; the display shows Fn1.
c. Press TARE until display shows Fn9.
d. Press MODE to enter. The display shows Sd.on or previously active option.
e. Press ZERO to select between Sd.on or Sd.oFF.
f. Press MODE to confirm and exit the current function. The display shows Fn10.
g. Press MODE to enter the next function, or press ZERO to exit. When ZERO is pressed, the display shows SAVE. The
user can press MODE (to save the changes made) or ZERO (to exit without saving).