EasyManuals Logo

Directed Electronics Valet 561T Installation Guide

Directed Electronics Valet 561T
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
© 2005 Directed Electronics—all rights reserved
3311
The LED will now report the last system shutdown by flashing for one minute in the following grouped patterns:
The LED will stop flashing when the ignition is turned on.
rreeaarr ddeeffooggggeerr ccoonnttrrooll
The rear defogger output has a factory default setting of
OONN
. Do not connect the Blue/White wire if this feature
is not to be used.
ttiimmeerr mmooddee
This unit can be programmed to start and run the engine every three hours. The engine will run for the pro-
grammed run time and then shut down. After three hours, the unit will restart the engine. A maximum of six
cycles can occur.
IIMMPPOORRTTAANNTT!!
Timer Mode should be used only in open areas. Never start and run the vehicle in
an
enclosed space such as a garage or carport.
TToo eenntteerr TTiimmeerr MMooddee::
1. Turn the ignition on.
2. Press and HOLD the activation input to the remote start.
3. Turn the ignition off while holding the activation input.
LLEEDD SSHHUUTTDDOOWWNN
FFLLAASSHHEESS MMOODDEE
One System timed out
Two Over-rev shutdown
Three Low or no RPM
Four Transmitter Shutdown (or optional push-button)
Six (-) Shutdown
Seven (-) Neutral safety shutdown (H2/6 BLACK/WHITE)
Eight Wait-to-start timed out

Other manuals for Directed Electronics Valet 561T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Directed Electronics Valet 561T and is the answer not in the manual?

Directed Electronics Valet 561T Specifications

General IconGeneral
BrandDirected Electronics
ModelValet 561T
CategoryRemote Starter
LanguageEnglish

Related product manuals