COMMAND REFERENCE PTU-D46 User’s Manual (v2.14.0)
Syntax
Enable verbose ASCII feedback: FV<delim>
Enable terse ASCII feedback: FT<delim>
Query ASCII feedback mode: F<delim>
Example
FV *
PP * Current pan position is 0
FT *
PP * 0
F * ASCII terse mode
4.5.5 Controller Firmware Version Query
Description
Query specifies the version and copyrights for the pan-tilt controller
firmware.
Syntax
V<delim>
Example
V * Pan-Tilt Controller v2.12.1d1(C14/E), (C)2003 Directed Perception, Inc., All
Rights Reserved
4.5.6 Outside Supply Voltage and Controller Temperature Query
Description
The D46 hardware includes sensors for the internal case temperature and the
input voltage supplied to the controller power receptacle. This query
measures and prints the controller temperature and input supply voltage.
Syntax
O<delim>
Example
O * Input 30 VDC @ 86 degF
4.6 Power Control Commands & Queries
A key advantage of the constant current motor control drivers used in the Pan-Tilt Controller
is that it allows the current consumed by the pan-tilt unit to be controlled via simple unit
commands. These capabilities are useful for battery powered operation (see Section 7), reducing
unit heat generation, and extending the rated life of the motor driver circuitry.