Service - 102 FX30/FXT30 Operator’s Manual
10 Hour
Clean Vacuum Air Filter
Clean filter every 10 hours or as needed.
To clean filter:
1. Remove filter from canister.
2. Run low pressure water into inside of filter.
3. Allow filter to dry completely before returning
to canister.
Check Spray Nozzle
Check spray nozzle every 10 hours. Ensure that
water sprays from nozzle in a fan pattern. Clean
or replace nozzle as necessary.
Breathing crystalline silica dust may cause lung disease.
Cutting, drilling, or working materials such as concrete, sand, or rock
containing quartz may result in exposure to silica dust.
To help avoid injury:
Use water spray or other means to control dust.
Use appropriate breathing protection when exposed to silica dust.
Refer to U.S. Department of Labor Occupational Safety and Health Administration guidelines to
learn more about appropriate breathing protection and permissible exposure limits.
NOTICE: Do not use high pressure
water or air to clean filter. Filter will be
damaged.
j33om024h.epsj33om024h.eps
j33om026h.epsj33om026h.eps