XT1600 Operator’s Manual Service - 81
50 Hour
CMW
Change Engine Oil and Filter (Initial)
Change engine oil and filter after 50 hours.
1. Remove large cover plate under unit to
access drain (3, on side of pan).
2. Drain crankcase while oil is warm.
3. Replace filter (4).
4. Close drain and install cover.
5. Add DEO at fill (1) until oil level is at highest
line on dipstick (2).
Change Hydraulic Filter (Initial)
Change hydraulic filter after 50 hours. Remove
floor panel to access filter (shown.)
Check Pump Drive Belt Tension
Check pump drive belt tension every 50 hours.
1. Turn off engine and remove key.
2. Apply moderate thumb pressure to top of belt.
3. Belt is properly tensioned when deflection (A)
is 1/4-3/8” (5-9.5 mm). To adjust, see
page 90.