7.5.1 Additional BC level parameters that can be configured
(available with enabled)
Display Description
HR - Enabling of operator present function
ON - Enabled
OF - Disabled
N.B.: Set only if and .
64 - Functioning of safety stop/closing command.
1-4 - Closing
1-6 - Safety stop
C5 - Step-by-step/opening command operation.
1-5 - Step-by-step
1-3 - Opening
RM - Radio receiver operation.
1-5 - Step-by-step
1-3 - Opening
AM - AUX plug-in card operation.
1-5 - Step-by-step
1-3 - Opening
PP - Setting step-by-step sequence from command
1-5.
ON - Opening-Stop-Closing-Stop-Opening
OF - Opening-Stop-Closing-Opening
S5 - Duration of STOP in step-by-step sequence from
command 1-5.
ON - Permanent
OF - Temporary
OD - Selecting opening direction.
LF - Opening to left.
RT - Opening to right.
The opening direction is intended by viewing the auto-
mation from the side being examined.
N.B.: Modification of status from RT to LF and vice
versa performs an automatic RESET of the card.