1.1 Safety functions
The CS12E control panel has the following safety functions:
- obstacle recognition with force limiting;
The maximum response time of the safety functions is 0.5 s. The reaction time to a faulty safety
function is 0.5 s.
The safety functions comply with the standards and performance level indicated below:
EN ISO 13849-1:2008 Category 2 PL=c
EN ISO 13849-2:2012
The safety function cannot be bypassed either temporarily or automatically. Fault exclusion
has not been applied.
The manufacturer Entrematic Group AB, with headquarters in Lodjursgatan 10, SE-261 44 Land-
skrona, Sweden, declares that the Entrematic CS12E type control panel complies with the
conditions of the following EC directives:
2014/30/EU (EMCD)
2014/35/EU (LVD)
2014/53/EU (RED)
L a n d s k r o n a , 0 7 - 0 9 - 2 0 1 8 M a t t e o F i n o
President & CEO)
2. EC Declaration of Conformity
3. Technical specifications
i
N.B.: The given operating and performance features can only be guaranteed with the
use of DITEC Entrematic accessories and safety devices.
Description NES300EH NES400EH NES600EH NES600EHSF
Power supply 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz 230 V~ 50/60 Hz
Motor output 24 V 12 A max 24 V 14 A max 24 V 16 A max 24 V 16 A max
Accessories power supply 24 V
0,3 A max 24 V 0,3 A max 24 V 0,3 A max 24 V 0,3 A max
Operating temperature
-20 °C +55 °C
-20 °C +55 °C
-20 °C +55 °C
-20 °C +55 °C
Storable radio codes
100
200 [BIXMR2]
100
200 [BIXMR2]
100
200 [BIXMR2]
100
200 [BIXMR2]
Radio frequency 433,92 MHz 433,92 MHz 433,92 MHz 433,92 MHz