GENERAL SAFETY PRECAUTIONS
@
This instailation manual is intended for professionaily competent personnel only. Instailation, electrical connections and adju-
stments must be performed in accordance with Good Working Methods and in compliance with applicable regulations. Before
installing the product, carefuily read the instructions. Bad instailation could be hazardous. Before instailing the product, make sure
it
is in perfect condition. For repairs or replacements of products only original spare
parts
must be used.
1.
TECHNICAL DATA
Refer to technical data and CE declaration of conformity contained in the manuals for BIS- TEN-VOLO-REX automations.
2. ELECTRICAL CONNECTIONS
WARNING: Link up all N.C. contacts (if not used) by means of jumpers. The terminal bearing the same number are equivalent.
2.1 CONTROLS
Control Function
Description
1____
2
N.O. AUTOMATIC CLOSING
The automatic closing function is enabled by a permanent contact.
The selector ComH-ComK and ComE automaticaily selects the auto-
matic closinn.
1____
3A
N.O. OPENING SIDEA
it starts the opening operation.
1___
38 OPENING SIDE B
1____ 4
N.O.
CLOSE It starts the closing operation.
1-.....-
8
N.C. REVERSAL SAFETY
Reverses movement (re-opens) during closing.
CONTACT
1-.....-
9
N.C. STOP
It
stops any movement.
When the contact is open, every normal and
emergency function is excluded. Warning: when the contact is closed
again, the door will resume the interrupted manoeuvre.
1 ____
28
N.O.
LOCKING EXCLUSION
The closed contact puts off duty the door wing locker. With ComH-
ComK and ComE exclusion takes place automaticaily in bi-directional
total and partial onenina positions.
RESET ComE
Contacl 1-28 also permits to cancel the operating mode set by ComE.
If ComE breaks down, and consequentiy the operating mode of the
door becomes impossible to modify, keep contact 1-28 closed for at
least 60 seconds, with ComE disconnected, and the electric board wiil
return to the bi-directionalltotal mode with DISABLED automatic clo-
sure lif 1-2 are not connected),
RESET REMOTE SETIINGS
In addition, when keeping contact 1-28 closed for at least 60 s after
having first disconnected and enabled the Dir, the electronic control
loanel aoes back to the remote software settinas.
1 ____ 29
N.O. RESET
It cancels ail acquired data. After 3 s the automation can proceed with
a new acquisition.
27 ____ 3A
N.O. PARTIAL OPENING SIDE A It causes a partial opening.
27 ___
3B
N.O. PARTIAL OPENING SIDE B
Q
IP1A4Q -