7. EXAMPLE OF APPLICATION WITH COME SELECTOR
The automation opens with Radar's controls 1-3A, 1-3B, it closes automatically according to the function chosen on the se-
lector.
It carries out the security function over the passage way by means of Cel photocells,
With selector in STOP position every normal and emergency working is cut off,
Contact 1-4 can be connected to a button to achieve a closing control.
As contact 1-8 is independent from the selector, it will be necessary to make a jumper if it is not used,
As contact 1-9 is to be considered in series to the STOP, set by the selector, it will be necessary to make a jumper if it is not
used.
Contact 1-29 can be used to RESET the electronic control panel