9. Routine maintenance plan
Perform the following operations and checks every 6 months according to intensity of use of the
automation.
- Visually check that the gate, the fixing brackets and existing structure have suitable mechanical
strength and are in good condition.
- Check the gate-gearmotor alignment, the distance (2-3 mm) between the throat of the pinion
and the crest of the rack.
- Clean the wheels sliding guide, the rack and pinion of the gear motor and slightly lubricate
the rack and pinion of the gearmotor. Manually check that the gate slides evenly and without
friction.
Connect the power supply and block the gearmotor (see RELEASE INSTRUCTIONS operations):
- Check that the limit switches are working correctly.
- Check the power adjustment.
- Check that all control and safety functions are working correctly.
WARNING: For spare parts, see the spares price list.