7. Installation
7.1 Preliminary checks
The given operating and performance features can only be guaranteed with the use of DITEC
accessories and safety devices.Unless otherwise specified, all measurements are expressed in
millimetres (mm).
Check the stability of the wing (derailing and lateral falls) and the sliding wheels and that the upper
guides do not cause any friction.
The sliding guide must be securely fixed to the ground for the full length within the doorway and
must have no irregularities that could hinder the movement of the gate.
The opening and closing stops must be fitted.
If the gate has slits, make sure they are covered to prevent shearing points.
Safety device should be installed at the end of the wing to reduce the collision force.
NOTE: make sure that the gate can not exit the sliding guides and fall.