Digital Monitoring Products Wireless Programming Options
2
ZONE INFORMATION
Wireless Programming Options Digital Monitoring Products
3
ZONE INFORMATION
16.10.3
TRANSMITTER
SUPRVSN TIME: XXX
Supervision Time
Press any top row key to select the supervision time required for the wireless
zone. Press COMMAND to accept the default time. Default is 60 minutes.
SELECT MINUTES:
0 3 15 60
Press the Select key under the required number of minutes. The transmitter
must check in at least once during this time or a missing condition is indicated
for that zone. 1100 Series transmitters automatically checkin based on the
supervision time selected for the wireless zone, no additional programming
is needed. If two zones share the same transmitter, the last programmed
supervision time is stored as the supervision time for both zones. Zero (0)
indicates an unsupervised transmitter.
Note: When the panel is reset or a receiver is installed or powered down and
powered up, the supervision timer restarts for all wireless zones.
16.10.4
LED OPERATION
NO YES
LED Operation
Select YES to turn on an 1142 Hold-up transmitter LED during Panic or
Emergency operation. Select NO to turn the LED off during Panic or Emergency
operation. The LED always operates when the transmitter case is open and the
tamper is faulted. Default is YES.
Note: For UL listed holdup installations, set LED Operation to NO.
16.10.5
NEXT ZONE NO YES
Next Zone
Select YES to return to the ZONE NO: - prompt to program a new zone. Select
NO to display the Alarm Action option.
1100 Series Key Fobs
For an 1100 Series Key Fob set the House Code from 1 to 50. See House Code programming in System
Options. Only zones 400 to 449 can be programmed as 1100 Series Key Fob zones. Refer to the 1100 Series
Key Fob Programming Sheet (LT-0706) supplied with the 1100X Wireless Receiver and the 1100 Series Key
Fob Install Guide (LT-0703) as needed.
After entering the zone number, enter a key fob user number.
16.11.1
KEY FOB USER
NUMBER: XXXX
Key Fob User Number
Enter the User Number (1-9999) used to identify the key fob user and their
arming and disarming authority. Default is blank.
16.11.2
TRANSMITTER
SERIAL#: XXXXXXXX
Key Fob Serial Number
Enter the eight-digit serial number found on the wireless device.
16.11.3
TRANSMITTER
SUPRVSN TIME: XXX
Key Fob Supervision Time
Press any top row key to select the supervision time required for the key fob
zone. Press COMMAND to accept the default time. Default is 0 for key fobs.
SELECT MINUTES:
0 3 15 60
Press the Select key under the required number of minutes. The key fob must
check in at least once during this time or a missing condition is indicated for
that zone. 1100 Series key fobs automatically checkin based on the supervision
time selected for the wireless zone, no additional programming is needed.
Zero (0) indicates an unsupervised transmitter.
Note: When the panel is reset or a receiver is installed or powered down and
powered up, the supervision timer restarts for all wireless zones.
16.11.4
NO. OF KEY FOB
BUTTONS: X
Number of Key Fob Buttons
Enter the number of buttons (1, 2, or 4) on the key fob being programmed.
Note: If the key fob is a one-button model, programming continues at the
Button Action section. Default button assignment for one-button key fobs is a
Panic Alarm (PN) with no output assigned.

Other manuals for DMP Electronics 263LTE-V5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics 263LTE-V5 and is the answer not in the manual?

DMP Electronics 263LTE-V5 Specifications

General IconGeneral
BrandDMP Electronics
Model263LTE-V5
CategoryControl Panel
LanguageEnglish

Related product manuals