Digital Monitoring Products Wireless Programming Options
6
ZONE INFORMATION
Wireless Programming Options Digital Monitoring Products
7
APPENDIX
20.12.2 LX-Bus Zone Type Defaults
These are complete spellings of the abbreviations used for
the zone types, such as Night and Exit.
Type - These are the abbreviations used for the zone types,
such as NT and EX.
Area - 1 to 32 for NT, DY, EX, A1, A2, and AR.
Fire Bell Out - Only available for FI, FV, and SV zones. Use
any output zone number listed.
Wireless - This indicates wireless equipment is being used.
DMP Wireless - These options are for use with the DMP
1100X Wireless Receiver.
FA Series Wireless - These options are for use with the
FA400-DMP Remote Wireless Receiver.
Message - A = alarm report, T = trouble report,
L = local, no report, (dash) = no report, D = door propped
(When SV zone is connected to 303 Silence/Reset Switch),
S = sensor reset/alarm silence, C = early morning ambush
cancel.
Output - These are the 6 on-board and 500 off-board relay
outputs, D1 to D16, and G1 to G20.
Action - This selects the action of the output:
S = steady, P = pulse, M = momentary, and F = follow
Swinger - The zone can be automatically shunted after a
programmed number of trips.
Prewarn - This selects the keypad address that sounds the
entry prewarn for this zone.
Entry Delay - This is the entry delay timer selected as the
default for this zone.
Retard Delay - Provides a programmed retard time before
an alarm initiates from a shorted zone. When used on an
arming zone, the retard delay occurs when the zone is
shorted before the armed state has changed. If the arming
zone has Maintain as the Style, the retard delay also occurs
when the zone returns to a normal state.
Presignal - Provides a keypad tone for zones in retard delay.
Retard must be YES before Presignal can be selected.
Fast Response - Provides a 167ms zone response instead of
the normal 500ms response.
Cross Zone - Provides cross zoning with any of the 574
zones.
Priority - Requires this zone to be in a normal condition
before the area can be armed.
Style - The abbreviations for arming zone style:
TGL = Toggle, ARM = Arm only, DIS = Disarm only,
STEP = Wireless arming, MNT = Maintain
Style
TGL
ARM
DIS
STEP
MNT
TGL
* Output Options: 1 to 6, 500 to 999, D1 to D16, G1 to G20. = Output action defaults to S. + = Set retard to YES before selecting presignal. = Zone functions not available.
Priority
N
or
Y
N
N
N
N
N
N
N
N
N
N
Cross Zone
N
or
Y
N
N
N
N
N
N
N
N
N
Fast Response
N
or
Y
N
N
N
N
N
N
N
N
N
N
Presignal
1
to
16
+
+
+
+
Retard Delay
N
or
Y
N
N
N
N
Entry Delay
1
2
3
or
4
1
Prewarn
1
to
16
1-16
Swinger
N
or
Y
Y
Y
Y
N
N
N
N
N
N
N
Armed
Short
Action
S
P
M
F
Output *
0
0
0
0
0
0
0
0
0
0
Message
A
T
L
D
S
C
A
A
A
A
A
A
A
A
A
A
Armed
Open
Action
S
P
M
F
Output *
0
0
0
0
0
0
0
0
0
0
Message
A
T
L
D
S
C
A
A
A
A
A
A
A
A
A
A
Disarmed
Short
Action
S
P
M
F
Output *
0
0
0
0
0
0
0
Message
A
T
L
D
S
C
T
A
A
A
A
Disarmed
Open
Action
S
P
M
F
Output *
0
0
0
0
0
Message
A
T
L
D
S
C
T
T
T
FA Series
Wireless
Normally Open
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
End-of-Line
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
INT Contact
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Check-in Time
None
10
30
60
60
60
60
60
60
60
60
60
60
60
60
DMP Wireless
LED Operation
N
or
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Supervision Time
0
3
15
60
60
60
60
60
60
60
60
60
60
60
60
EXT Contact N/O?
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Contact
INT
or
EXT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
Wireless
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Fire
Bell
Output *
0
0
0
Area
1
to
32
Type
--
NT
DY
EX
FI
PN
EM
SV
A1
A2
FV
AR
NT
DY
EX
FI
PN
EM
SV
A1
A2
FV
AR
XR500 Series LX-Bus Zone Information
Assign Disarm condition for NT, DY, EX, A1, and A2 only.
Assign Prewarn and Entry Delay for EX only.
Assign Retard and Presignal for FI, SV, A1, and A2 only.
Zones___________ to __________
Zone Type Defaults
NIGHT
DAY
EXIT
FIRE
PANIC
EMERGENCY
SUPERVISORY
AUXILIARY 1
AUXILIARY 2
FIRE VERIFY
ARMING
Serial NumberZone Name

Other manuals for DMP Electronics 263LTE-V5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics 263LTE-V5 and is the answer not in the manual?

DMP Electronics 263LTE-V5 Specifications

General IconGeneral
BrandDMP Electronics
Model263LTE-V5
CategoryControl Panel
LanguageEnglish

Related product manuals