Digital Monitoring Products Wireless Programming Options
b
Wireless Programming Options Digital Monitoring Products
1
SYSTEM OPTIONS
8.14
BYPASS LIMIT 0
Bypass Limit
Enter the maximum number of zones (0 to 8) that can be bypassed in any single area
when that area is being armed at a keypad. If more zones than the limit are in a
non-normal state or already bypassed at arming, arming does not occur and Arming
Stopped displays. The Bypass limit does not affect auto arming, keyswitch arming,
or remote arming. Entering 0 (zero) allows no limit. Default is 0 (zero).
8.15
HOUSE CODE: XX
House Code
When using a DMP wireless system, enter a house code between 1 and 50. When
using FA Series wireless enter 99. See Wireless programming in Zone Information.
Default is 0 indicating no wireless system is being used.
The DMP house code identies the panel, DMP receiver, and DMP transmitters to
each other. When operating, the DMP receiver listens for transmissions that have
the programmed house code and transmitter serial number.
Note: The exibility of DMP two-way wireless operation allows an existing house
code to be changed in the panel at any time. The transmitters may take up to two
minutes to learn the new house code and continue operation.
Note: When any wireless zone programming is changed in the panel, wireless
receiver zone programming is updated. At that point, all wireless zones display as
normal for approximately 1 minute, regardless of the actual state of the zone.
8.16
DETECT WIRELESS
JAMMING: NO YES
Detect Wireless Jamming
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system (1-50). When enabled and the wireless receiver detects jamming, a trouble
or alarm message displays in the Status List and is sent to the central station
receiver. Select YES to enable jamming messages to display in the Status List.
Select NO to disable jamming messages. Default is NO.
8.17
KEYPAD PANIC KEYS
ENABLED: NO YES
Enable Keypad Panic Keys
This option allows the two-button panic key operation selected at the keypad to
send the Panic, Emergency, or Fire message to the central station receiver. Select
YES to enable the two-button panic operation to operate. To disable the two-button
panic operation, select NO. Default is YES.

Other manuals for DMP Electronics XR500 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR500 SERIES and is the answer not in the manual?

DMP Electronics XR500 SERIES Specifications

General IconGeneral
BrandDMP Electronics
ModelXR500 SERIES
CategoryControl Panel
LanguageEnglish

Related product manuals