6. SERVICING
EN
17
CAUTION
CAUTION
In case the appliance fails to operate correctly after all checks have been carried out, shut off
the gas supply at the main gas tap and refer to the authorized service provider in your area.
When satisfied with the appliance, please instruct the user on the correct method of operation.
5.6.1 Test point
For models PI... MO... CU...
The test point is supplied loose with the appliance (see picture in FIG. 7 - PG. 37). Remove one burner
head, the injector and screw in test point fitting. The pressure is measured with the relevant burner gas
valve on high flame and with an inlet pressure of 2.75 kPa.
For models FO...
The test point is fitted on the main gas pipe. Remove the front plastic plaque (see picture in FIG. 8 - PG. 37)
and remove the screw. The pressure is measured with an inlet pressure of 2.75 kPa.
For models VN555
The test point is fitted on the main gas pipe. Remove the screw. The pressure is measured with an inlet
pressure of 2.75 kPa.
5.7 Duplicate data plate
After installation, the data plate may be consulted by opening the door of the oven or of the grill
compartments, or on the back of the instructions manual.
The date of manufacture can be deduced from the serial number: the 2nd and the 3rd figure indicate the
year, the 4th and the 5th figure the week. See the example below.
year week